• Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
  • Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
  • Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
  • Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
  • Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer

Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer

After-sales Service: 1 Year
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <5kg
Type: Universal Testing Machine
Maxcapacity: N/a
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
  • Overview
  • Product Description
  • Product Features
  • Product Parameters
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
ZC-300B
Accuracy Grade
200ms: 0.05% Plus or Minus 1 Word
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
5kg
Power Source
220V, 50Hz
Relative Humidity
5%~95%,No Dewing
Test Range
0.01ms~10000ms
Velocity Measurement
Instant Separating (Instant Closing) V
Time Measurement
12 Natural Switching (Closing) Time
Transport Package
Standard Box Inside and Wooden Box Outside
Specification
360X250X140mm
Trademark
KvTester
Origin
China
HS Code
903180909
Production Capacity
500/Month

Product Description

Product Description

ZC-300B circuit breaker analyzer can be used to test and measure the mechanical characteristic parameters of high voltage switch ( such as vacuum, six fluoride, less oil, oil and other power systems. The measurement data is stable, strong anti-interference ability, can be in the 500KV level and below the power station to do experiments, wiring is convenient, simple operation, is the most convenient tool for high-voltage switch maintenance test.

Product Features

The instrument can automatically identify the fracture opening and closing state, and according to the reference state corresponding to the fracture tip and operation.

Independent 12 fracture, can detect and indicate the connection state of the fracture, facilitate the user to check the wiring

The tester can store 50 groups of test results.

Large touch screen LCD display, advanced gray screen, without reflection or black in the sun, and English characters graphic menu.

Operation tips, user-friendly menu interface, easy to operate.

The instrument has powerful function of graphic analysis, and the waveform and measurement data are displayed on the same screen.

The utility model has the function of time delay protection, and the coil voltage can be automatically cut off after the circuit breaker is operated.

The instrument can be divided into electric and manual test.

For high and low voltage test, automatically find the lowest open or closing voltage.

Reclosing test, can do parameters test for open-closing, closing-open and open-closing-open etc.

Vacuum contactor (Single coil) parameter measurement.

Product Parameters

1. Time measurement:

    12 natural switching (closing) time
    The opening (closing) phase is not at the same time
    The difference between different periods of switching (closing)
    Closing (opening) Bouncing time (number of bounces)
    Internal trigger test range: 0.01ms ~ 10000ms, resolution: 0.01ms,
    External trigger test range: 0.01ms ~ 200000ms,
    Resolution within 999ms: 0.01ms,1000-9999ms: 0.1ms, and over 10000ms: 1ms.
    Accuracy within 200ms: 0.05%±1 word
2. velocity measurement : instant separating (instant closing) velocity
    Appointed time slot( stroke segment or angle segment) average velocity
3. velocity measurement range: 1mm sensor 0.01~25.00m/s,
    0.1mm sensor 0.001~2.50m/s
    0.5°angle sensor 1 cycle/ 0.5°
4. Travel measurement: Travel of moving contact (travel)
    Contact stroke (open distance)
    Over travel
    Overshoot or rebound stroke
5. Measuring range:
    linear sensor: 50mm
    measuring range: 0-50mm
    resolution :0.1mm
    Optional 100-1000mm linear sensor of any length
    Encoder: 360. Rotate sensor, measurement
    range: 0-1000mm, resolution :0.25.
6. Current resistance range: the maximum current 30 A, resolution: 0.01 A, 1000 Ω resistance,
    resolution: 0.01 Ω.
7. Instrument power supply: AC 220V ± 10%; 50 Hz ± 10%
8. DC power output: continuously adjustable DC20 ~ 270V, DC110V≤30A (short time), DC220V≤
    20A(short time). Power: 4400W.
9. External trigger voltage: AC/DC10-300V, current ≤120A
10. disconnecting switch measurement range
    (1) Voltage output: DC20~270V(adjustable)
    (2) Current output time: 0.01~10 s (settable)
    (3) Fracture signal maximum acquisition time: 10s
    (4) Measurable fracture closing, separation time, three-phase in synchronism , bounce time
         and frequency .
11. mainframe volume : 36×26×17cm
12. operating environment: -20ºC~+50ºC
13. relative humidity: ≤90%
 

Packaging & Shipping

 

Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
Large Touch Screen Circuit Breaker Timing Test Equipment High Voltage Switch Gear Analyzer
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now