ZC-501 AC/DC 70KV/10KVA High Voltage Tester (HIPOT) includes a digital display control box (referred to as test instrument) and a HV transformer.
The control box take numerical control technology, anti-interference ability, and compared with the previous generation of operating box, with small size, light weight, beautiful appearance and so on. Its output voltage range from 0 to 200V is adjustable continuously. It is used for voltage regulation control of calibration, test and test equipment. The operation is simple, compact and firm structure, reliable operation, convenient maintenance.
The HV transformer is a Oil-immersed single-phase transformer. This device is especially suitable for power systems, mining enterprises, scientific and research department to have insulation strength test under power frequency for all kinds of high-voltage electrical instrument, electrical components, insulation materials.
(1) Intuitive reading: this instrument uses digital LCD head, can directly display high voltage, instrument voltage and low voltage current, high voltage current test value, easy to test observation and record.
(2) Accurate measurement: all digital processing, built-in precision mathematical model, with high measurement accuracy, accurate test value.
(3) Accurate protection function: all digital processing, overcurrent protection value setting, timing voltage setting and overvoltage protection value setting are realized by digital, so that the protection is more accurate.
(4) Automatic timing: the instrument has time trigger function, the device automatically timing according to the set voltage value, so that the timing is more accurate and more effective.
(5) Easy to carry: small size, light weight, the volume of only 80% of similar products, it is very convenient to carry
Power Supply
(1)Voltage: AC220V±10%
(2)Frequency: 50Hz
(3)Max current: 45.5A
Environment requirements
(1)Ambient temperature: -10ºC~40ºC
(2)Relative humidity: ≤80%
Control box output capacity
(1)Control Box output voltage: AC 0~200V
(2)Control box output current: AC 0~50A
(3)Time: 0~999s
HV Transformer's parameters
(1) Capacity: 10KVA
(2) Input Voltage: 0~200V
(3) Input Current: 0~50A
(4) Output AC HV Voltage: 0~70kV
(5) Output AC HV Current: 0~150mA
(6) Output DC HV Voltage : 0~98kv
(7) Output DC HV Current: 0~150mA
(8) Output Meter Voltage: 0~100V