China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester

Warranty: 1 Year
Max Diameter of Workpiece: >3200mm
Mass Scope of Workpiece: <900kg
Type: Universal Testing Machine
Maxcapacity: <1000KN
Accuracy Grade: 0.1%B
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZC-206
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Weight
0-100Kg
Power Source
220V 50Hz
Scanning Mode
Linear Scan Distribution
Transport Package
Standard Box Inside and Wooden Box Outside
Trademark
KvTester
Origin
China
HS Code
903180909
Production Capacity
500/Month

Product Description

Description

China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester

Transformer winding deformation tester quantizing windings parameter changes in different frequency domain, according variance, range, extent and trend of frequency response, to decide deformed extent of the windings, and then decide if the transformer was badly damaged or needed major repairs according the testing results. The device with compact structure, it is easy to operate.

Features

1. Use high-speed, high integration microprocessor to sample and control.

2. Use USB to connect the notebook PC and device.

3. Use wireless blue-tooth interface to communicate the notebook PC and device. The high-speed microprocessor integrated with device, need not move the computer during the field test.

4. Hardware cassette mechanism adopts DDS (from America), can correctly detect the breakdown :distortion, swell, shift, tilt, inter-turn short circuit deformation and contacting short circuit inter-phase.

5. High resolution dB to test, dual channel, 16 bit A/D sampling (the wave from curve will change obviously if change the tapping switch during the field tests. )

6. The software can adjust the output signal range, the maximum amplitude peak±10V.

7. The computer automatically generating the test results to be Word document.

8. Use precision , high stability components, repeat to test , the measurement repetition rate >99.5%.

9. Finished circuit boards, the surface with special treatment.

10. The device with two measurement system: linear scan and sectional scan.

11. Amplitude-frequency characteristic complies the national technical specifications.

12. Test data automatic analysis system, horizontal compare the similarity of A,B ,C, the results as below:
      1.conformance is very good
      2.conformance is good
      3. conformance is bad
      4.serious deformation
      Vertical compare A-A,B-B,C-C, obtain the original data to compare the winding deformation with the test data in the same phase, the results as below:
      1.normal
      2.slight deformation
      3.moderate deformation
      4.serious deformation

13. Automatically generating Word document,convenient for customers to save and print.
14. Totally meet the technique conditions of DL/T911-2004:Survey of Frequency Response Analysis on Winding Deformation of Transformers.

Product Parameters

Scanning mode

linear scan distribution

Sweep frequency measurement range

(1kHz)~(2MHz) 2000 Sweep frequency point; resolution ratio 1kHz range

Measurement accuracy

0.1dB

Scanning frequency accuracy

<0.01%

Scanning measurement range

(0.5kHz)~(1MHz)      2000 Sweep frequency

(0.5kHz)~(10kHz)    resolution ratio 0.02kHz

(10kHz)~(100kHz)    resolution ratio 0.02kHz

(100kHz)~(500kHz)    resolution ratio 1 kHz

(500kHz)~(1000kHz)    resolution ratio 1 kHz


China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
China Manufacturer Transformer Sweep Frequency Response Analysis Winding Deformation Displacement Distortion Tester
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now