Customization: | Available |
---|---|
Max Diameter of Workpiece: | >3200mm |
Mass Scope of Workpiece: | <900kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ZC-300B circuit breaker analyzer can be used to test and measure the mechanical characteristic parameters of high voltage switch ( such as vacuum, six fluoride, less oil, oil and other power systems. The measurement data is stable, strong anti-interference ability, can be in the 500KV level and below the power station to do experiments, wiring is convenient, simple operation, is the most convenient tool for high-voltage switch maintenance test.
The instrument can automatically identify the fracture opening and closing state, and according to the reference state corresponding to the fracture tip and operation.
Independent 12 fracture, can detect and indicate the connection state of the fracture, facilitate the user to check the wiring
The tester can store 50 groups of test results.
Large screen LCD (320 * 240) LCD display, advanced gray screen, without reflection or black in the sun, and English characters graphic menu.
Operation tips, user-friendly menu interface, easy to operate.
The instrument has powerful function of graphic analysis, and the waveform and measurement data are displayed on the same screen.
The utility model has the function of time delay protection, and the coil voltage can be automatically cut off after the circuit breaker is operated.
The instrument can be divided into electric and manual test.
For high and low voltage test, automatically find the lowest open or closing voltage.
Reclosing test, can do parameters test for open-closing, closing-open and open-closing-open etc.
Vacuum contactor (Single coil) parameter measurement.
1.Time measurement:12 channel
The inherent opening (closing time)
Opening (closing) in different phases
Opening (closing) in different period
The closing (opening) bounce time (bounce)
Test range:0.01ms~10000ms
Accuracy:within 1ms~100ms accuracy 0.5%±2words,
> 100ms accuracy 1%±2 words
Velocity measurement:breaking(just close)velocity
Average speed of a specified period of time (travel or angle)
2. Speed range:1mm sensor 0.01~25.00m/s,
0.1mm sensor 0.001~2.50m/s,
0.5° angle sensor0.01~25.00m/s
Universal sensor:0.01~10.00m/s
3.Stroke measurement:Moving contact stroke (stroke)
Contact travel (opening)
Overshoot stroke or reverse stroke (overshoot)
4. Sensor measurement range:
Linear displacement sensor 50mm,resolving power:0.1mm,stroke 0.1~50mm
Linear displacement sensor 300mm,resolving power:0.1mm,stroke 10~300mm
Linear displacement sensor 500mm,resolving power:1mm,stroke10~500mm
360°Line sensor:360о, resolving power :0.5о, stroke 5mm~999mm
Universal sensor:resolving power:0.1mm,stoke 5mm~999mm
5. Current measurement:The maximum current value of the opening (closing) coil be displayed.
6.Display: 320 x 240 LCD screen, adjustable contrast
7.Data storage: can store 100 sets of measurement data
8.Printer: high speed thermal printer
9. Power:AC/DC 220V ± 10%;50Hz ± 2%
10.DC power supply: output voltage: 35 ~ 265V continuously adjustable, output current: ≤ 15A (short time)
11. Size:360×250×140mm
12.Environment: -10ºC~+50ºC
13.Relative humidity:≤90%