• Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
  • Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
  • Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
  • Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
  • Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
  • Variable Frequency Series Resonance Testing System High Voltage Hipot Tester

Variable Frequency Series Resonance Testing System High Voltage Hipot Tester

After-sales Service: 1 Year
Warranty: 1 Year
Type: Universal Testing Machine
Accuracy Grade: 0.02 Class
Load Way: Electronic Load
Loading Method: Static Load
Customization:
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ZCVF-A
Display
Digital
Control
Computer Control
Weight
100-500Kg
Power Source
AC220V
Rated Input Voltage
380V ± 10% (Three-Phase), 50Hz
Rated Output Capacity
300kVA
Max. Output Voltage
300kv
Max. Output Current
1A Single Piece
Regulating Range of Frequency
30Hz - 300Hz
Customization
Customized System According to Requirement
Transport Package
Wooden Box
Specification
Customized
Trademark
KvTester
Origin
China
HS Code
9031809090
Production Capacity
500/Month

Product Description

Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Product Introduction

Series resonant system are widely used in Electric Power, Oil, Chemical Industry, etc., applicable to connecting and preventing tests for capacitive equipment with high-capacity, high-voltage. It is composed by control cabinet, excitation transformer, high voltage reactor, high voltage divider. There are two kinds of control cabinet, more than 20KW is console, less than 20KW is portable case, which is composed by controller and filter device. Its main function is change 380V or 200V (the amplitude and frequency are fixed) frequency sine wave AC power into sine wave (amplitude and frequency are adjustable), and supply power for the whole system. The function of excitation transformer is to boost the output voltage of the power source to the proper measured voltage. High voltage reactor L is important component of the resonant loop. This system applies to AC voltage withstand tests of 10KV, 35KV, 110KV, 220KV, 500KV polythene cable , 60KV, 220KV, 500KV GIS, large transformers, generators, transformer induced voltage withstand test and ground resistance measurement.
 

Product Features

 
1. High stability and reliability. Voltage and frequency output is stable, design for electromagnetic compatibility is reasonable, perfect protecting protection, the system is still good after several tests high voltage to earth short circuit , meanwhile the system with strong over-load ability.
 
2. Powerful automatic tuning function. When the system automatic tuning, auto scanning from 30Hz to 300Hz, display the scanning curve, customers can clearly view the tuning process; after finished the scanning, system will find out the resonant point, makes frequency fine tuning within its range ±5Hz with resolution 0.01Hz, finally accurately lock the resonant frequency.
 
3. Multi test modes: automatic tuning + manually regulating voltage, automatic tuning + automatic regulating voltage, manually tuning + manually regulating voltage, we suggest the mode: automatic tuning + manually regulating voltage, which can fast find out the resonant point, it also can control the measurement process by manually regulating voltage, more safe.
 
4. Friendly man-machine communication interface, parameters setting, test controlling , test results displayed in one screen, clear and visible, with auto timing and operation indicating functions, full touching screen, can store and review the test data.
 
5.Perfect protecting functions, with zero position protection (forbid the system to start if the voltage output controlling knob was not at the zero position), over-voltage protection, over-current protection and flashover protection, ensure the safety of the system.



Product Parameters
 
Rated input voltage
380V ± 10% (three-phase), 50Hz or 60Hz
Rated output capacity
300kVA
Max. output voltage
300kV
Max. output current
1A single piece
Regulating range of frequency
30Hz-300Hz
Insulation level
under 1.1 times and keeping 1 min, normal
Allowable running time (duty cycle)
Continuous running for 60 mins on, 120 mins off
Quality factor for the system itself
Q ≥ 50 (at F=30Hz)
System measuring accuracy
grade1.0 effective value

Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester
Variable Frequency Series Resonance Testing System High Voltage Hipot Tester

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now