10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter

Product Details
Customization: Available
Max Diameter of Workpiece: >3200mm
Type: Universal Testing Machine
Manufacturer/Factory & Trading Company
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
20
Year of Establishment
2008-09-18
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
  • 10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
Find Similar Products

Basic Info.

Model NO.
ZC-221-029
Maxcapacity
<1000KN
Accuracy Grade
1
Load Way
Electronic Load
Loading Method
Static Load
Display
Digital
Control
Manual Control
Measuring Range
0.1%< Tg δ< 100%
Warranty
1 Year
Harmonic Adaptation
<3%
Transport Package
Wooden Box
Specification
460(L)*345(W)*350(H)
Trademark
KvTester
Origin
China
HS Code
9031809090
Production Capacity
500/Month

Product Description

Description

10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
 
This device is a high accuracy tester to test tangent of dielectric loss and capacitance of various HV electrical equipments for generations and substations. It also applies to workshop, laboratory and R&D institutions.high

Features

1. LCD display, mass storage data, the instrument data can be exported through the U disk, and can generate a work report.

2. Many test modes: internal high voltage, external high voltage, internal standard, external standard, positive connection method, reverse connection method, self excitation method in a variety of ways to test; under the high pressure of outside the standard can do the high voltage of more than 10kV) dielectric loss test. 
3. CVT test one-step process: to test the full sealed CVT (capacitive voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C2, C1 testing at the same. The instrument can also test the CVT ratio and voltage angle difference. 
4. Multiple protections safe and reliable: with input voltage fluctuation, output short circuit, overvoltage, over current, temperature and other multiple protection measures. 
5. The instrument can be used for measuring the high-voltage electrical equipment of the non grounding or grounding, and can measure the capacitance of the capacitor voltage transformer tgδ and the main capacitor C1 and C2. 
6. The instrument is equipped with high voltage transformer, and takes safety protection measures against lightning, zero switching.

Product Parameters
High voltage output: 0.5~10KV Each files to increase 500V, a total of twenty files, capacity: 1500VA
Accuracy tg δ: ±(reading*1.0%+0.04%)
Cx: ± (reading*1.0%+1PF)
Resolving power tg δ: 0.01%,Cx:1pF
Measuring range 0.1%< tg δ< 100%
3PF<Cx<60000PF
10KV,Cx≤30000PF
5KV, Cx≤60000PF
Power supply AC 220V±10% ,50±1Hz
Measurement method Power frequency: 50Hz
Pilot frequency: 45Hz/55Hz Automatic frequency conversion
Harmonic adaptation ≤ 3%
Service condition -15ºC-50ºC relative humidity<80%
Outline dimension 460(L)*345(W)*350(H)
Weight 35KG

10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
10kv Automatic Transformer Dissipation Factor Tester Tan Delta Meter
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier