ZC-102F CT volt-ampere characteristic tester is a fully automated CT/PT characteristic tester. It is a specialized tester for relay protection and high voltage insulation. The instrument can complete tests include: CT volt-ampere characteristic test, CT variable ratio polarity test, CT polarity test, CT primary current test, PT volt-ampere characteristic test, PT variable ratio polarity test, PT polarity test, automatic calculation of inflection point voltage-current value, variable ratio difference value, 5% or 10% error curve value, etc.
ZC-102F CT volt-ampere characteristic tester adopts imported core devices and strict manufacturing process to ensure stable and reliable product performance; the instrument panel adopts ergonomic design, easy to operate, one person can complete all the testing work; the software has powerful functions, automatically calculates and gives the test results; the self-contained U disk storage function, combined with PC software, generates complete testing. Reporting, data management is simple and efficient, reducing the workload of testers; the instrument has its own micro printer, which can print test data and curves in real time. This instrument is a professional testing instrument with complete functions, suitable for laboratory and field testing, and widely praised by users.
1. Only setting the test voltage, current and step size, the device can automatically boost voltage and automatically plot the volt-ampere characteristic test curve, eliminating the tedious work of manual voltage regulation, manual recording and curve tracing. Quick, simple and convenient.
2. It can test the volt-ampere characteristics, variable ratio and polarity of CT/PT, error curve of 10%, angle error and ratio error.
Type | ZC-102F | |
Application | Test CT: excitation characteristics, variable ratio, polarity, ratio error and angle error etc. Test PT: excitation characteristics, ratio, polarity, secondary winding resistance, ratio error, etc. |
|
Working power supply | Input voltage | 185Vac~250Vac |
Allowable Input Voltage | 85Vac~264Vac | |
Frequency | 50/60Hz | |
Allowable frequency | 45Hz~65Hz | |
Input power | 5000VA | |
Connector | Standard AC socket 60320 | |
Built-in booster | Output range | 0~2500V(220V power) |
0~20A | ||
Volt-ampere characteristic test reference load capability | 1A/2500V | |
2A/1500V | ||
5A/600V | ||
10A/220V | ||
20A/30V | ||
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.2 class Variable Ratio Measurement Accuracy: 0.2 class |
|
External booster | Output range | 0~4000V/1A |
Volt-ampere characteristic test reference load capability | 1A/4000V | |
Measurement Accuracy | Secondary voltage ≥50V,secondary current ≥200mA: Accuracy of Volt-ampere Characteristics: 0.2 class Variable Ratio Measurement Accuracy: 0.2 class |
|
Up-flow Reactor | Output range | 0~600A |
Volt-ampere characteristic test reference load capability | 800VA | |
Measurement Accuracy | Variable Ratio Measurement Accuracy:<0.2% | |
Environment condition | Operating temperature | -10ºC~+50ºC |
Storage temperature | -25ºC~+70ºC | |
Relative humidity | 5%~95%,No condensation | |
Physical characteristics | Size | 425×300×290mm3 |
Weight | ≈26kg(not include accessories ) |