Customization: | Available |
---|---|
Max Diameter of Workpiece: | >3200mm |
Mass Scope of Workpiece: | <900kg |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
ZC-121A PT excitation characteristic tester is developed specifically for PT excitation characteristic, no-load characteristic measuring equipment factory according to national standard "GB / T 22071.2-2008 transformer test guidelines for Part 2: electromagnetic voltage transformer" provisions,combined with the actual needs of the transformer manufacturers, and China Electric Power Research Institute, Wuhan High Voltage Research Institute jointly.The instrument uses advanced DSP+FPGA technology, tracking and measuring speed, to capture the data accurately, more powerful, easy to use, in the domestic leading level.
1. Full automatic acquisition, measurement, display, storage, print all measurement parameters and excitation characteristic curve (voltage, current, power, frequency, etc.).
2. Ultra large scale, can automatically and manually measure the set point of the excitation data.
3. Supports up to 100 sets of preset test parameters, when doing the test only needs to enter the number of preset parameters of the test sample can be transferred out of the sequence value of the capture point, greatly improving the efficiency of the test.
4. Built-in large capacity memory, storage test data, and the industry standard communication interface (RS232) uploaded to the PC machine, random software to achieve data upload, automatic generation and editing the typical test report, for the technical management and archiving.
5. With the function of over-voltage and over current protection, the protection value is automatically adjusted according to the test parameters, which is simple and convenient and can ensure the safety of the test equipment.
6. Aslo can do the test for the voltage (current) transformer, arc suppression coil volt ampere characteristic test.
Product Parameters
Voltage measurement | 0-300V | 0.2class |
Current measurement | 0-20A | 0.2class |
Active power | 0-6KW | 0.5class |
Frequency | 40-75Hz | 0.1class |